Column

One layer of any 5/8” (15.9 mm) DensArmor Plus® Fireguard® panel applied without horizontal joints and parallel to 1-5/8” (41 mm) steel studs located at each corner of TS8x8x0.250 tube steel column with 1” (25 mm) Type S drywall screws 24” (610 mm) o.c. Steel cornerbead, 1-1/2” (38 mm) flanges, applied with 1” (25 mm) Type S drywall screws 12” (305 mm) o.c. in each flange. Joint compound 1/16” (2.0 mm) thick applied over corner bead.

1 Hour Column UL Installation Assembly
Hourly Rating: 1-hour
STC Rating:
Fire Test Reference: UL X528, GA CM 1851
Sound Test Reference:
Approved for Assembly:
DensArmor Plus® Fireguard C® Products
DensArmor Plus® Fireguard® Products
DensElement® Barrier Sheathing
DensGlass® Fireguard® Sheathing
DensShield® Fireguard® Tile Backer
ToughRock® Fireguard C® Products
ToughRock® Fireguard X® Mold-Guard® Products
ToughRock® Fireguard X® Products
ToughRock® Lite-Weight Fire-Rated Products