DensDeck® StormX® Prime Roof Board provides a higher level of performance and is recommended for mechanically fastened, adhered and partially adhered roofing systems. This Roof Board is FM classified for Very Severe Hail (VSH) in approved single ply membrane assemblies. This gypsum cover board was the first of its kind to pass FM VSH in a single ply assembly, when using an adhered standard 60 mil TPO bareback membrane. DensDeck® StormX® Prime Roof Board is approved in more single ply VSH systems than all over cover boards combined and is included in thousands of approved systems that can be found in FM Roof Nav.
R Value | °F•ft2•hr/BTU (m2•K/W): .67 |
ASTM Type | ASTM C473; ASTM E661; ASTM E96; ASTM C518; ASTM C1177; ASTM C473;ASTM D3273 |
Fire Rating | Type X |
Mold Resistance | No (10/10) |
Flexural Strength, parallel, lbf. min. (N) | ≥=200 (888) |
Flute Spanability2 | 18″ (457mm) |
Permeance, Perms (ng/Pa•S•m2 ) | >17 (>970) |
Linear Variation with Change in Temp., in/in/°F (mm/mm/°C) | 11.7×10–6 (459333×10–6) |
Linear Variation with Change in Moisture | 6.25 x 106 |
Water Absorption, % max3 | 5 |
Compressive Strength, psi nominal | 1800 |
Surface Water Absorption, grams, nominal | 1.0 |
Length | standard: 4′ (1219 mm) and 8′ (2438 mm) ± 1/4( (6.4 mm) |
Width | standard: 4′ (1219 mm) ± 1/8″ (3 mm) |
Thickness | nominal: 5/8″ (15.9 mm) ± 1/32″ (.8 mm) |
Weight | nominal: 3.0 (14.6) |
Certifications may vary by production location, please contact local representative for more information.
1. Tested in accordance with ASTM C473 method B.
2. Tested in accordance with ASTM E661.
3. Tested in accordance with ASTM E96 (dry cup method).